Đại lý honeywell Minimax XP

Đại lý honeywell Minimax XP

Thông số kỹ thuật thiết bị dò khí Minimax XP

Standard Specification
Gases                             DetectedRange       Level 1         Level 2         STEL              TWA
Oxygen (O2 )                   0 to 30% v/v         23.5% v/v    19.5% v/v     n/a                n/a
Carbon Monoxide (CO)       0 to 999 ppm       35 ppm         100 ppm      400 ppm        35 ppm
Hydrogen Sulphide (H2 S)  0 to 250 ppm       10 ppm         15 ppm         15 ppm         10 ppm
Sulphur Dioxide (SO2 )       0 to 150 ppm       2 ppm           5 ppm            5 ppm          2 ppm
Chlorine (Cl2 )                   0 to 50 ppm         0.5 ppm        1 ppm            1 ppm         0.5 ppm
Hydrogen Cyanide (HCN)   0 to 100 ppm        5 ppm           10 ppm         10 ppm           5 ppm
Nitrogen Dioxide (NO2 )     0 to 150 ppm       3 ppm            5 ppm            5 ppm           3 ppm
Ammonia (NH3 )               0 to 100 ppm        25 ppm         50 ppm         35 ppm          25 ppm
Hydrogen (H2 )                 0 to 999 ppm       100 ppm        500 ppm         n/a                n/a

đại lý honeywell Minimax XP | nhà phân phối honeywell Minimax XP | thiết bị dò khí honeywell Minimax XP

Construction
General Serviceable, portable single gas monitor for personal protection against Oxygen and toxic gas hazards
Calibration Time between calibrations is maximized utilizing cell decay compensation facility. The maximum time between calibrations is 12 months
Operating Life Sensor (replaceable) Minimum of 2 years Battery (replaceable) 3 years*
Operating Temperature -20°C to +50°C (-4°F to +122°F) (temperature compensated)
Humidity 5-95% RH (non-condensing)
Audible Alarm 95dB @ 10cm (3.9″)
Visual Alarm High intensity Red LEDs
Vibrating Alarm Standard
Display Ultra clear backlit LCD displays gas levels & instrument status
Sensor Type Electrochemical (replaceable)
Battery Type Lithium CR2, 3.0v (replaceable)
Diagnostics Self-test of circuitry, battery, LCD, and software. Sensor test using patented Reflex † sensor technology

 

Environmental
IP Rating IP54 (minimum)
Intrinsic Safety North America: Class 1, Div 1, Groups A, B, C, D, T4 (UL/cUL) Europe: II 2G EEx ia IIC T4 (ATEX)
RFI/EMC CE EN50270:1999 and EN55011
Dimensions 93mm (H) x 50mm (W) x 27mm(D) (3.6″ x 2″ x 1.1″) excluding clip
Weight Toxic 81.5g (2.8oz) Oxygen 93.0g (3.3oz)

Trả lời