Đại lý honeywell Minimax XP
Thông số kỹ thuật thiết bị dò khí Minimax XP
Standard Specification |
Gases DetectedRange Level 1 Level 2 STEL TWA |
Oxygen (O2 ) 0 to 30% v/v 23.5% v/v 19.5% v/v n/a n/a |
Carbon Monoxide (CO) 0 to 999 ppm 35 ppm 100 ppm 400 ppm 35 ppm |
Hydrogen Sulphide (H2 S) 0 to 250 ppm 10 ppm 15 ppm 15 ppm 10 ppm |
Sulphur Dioxide (SO2 ) 0 to 150 ppm 2 ppm 5 ppm 5 ppm 2 ppm |
Chlorine (Cl2 ) 0 to 50 ppm 0.5 ppm 1 ppm 1 ppm 0.5 ppm |
Hydrogen Cyanide (HCN) 0 to 100 ppm 5 ppm 10 ppm 10 ppm 5 ppm |
Nitrogen Dioxide (NO2 ) 0 to 150 ppm 3 ppm 5 ppm 5 ppm 3 ppm |
Ammonia (NH3 ) 0 to 100 ppm 25 ppm 50 ppm 35 ppm 25 ppm |
Hydrogen (H2 ) 0 to 999 ppm 100 ppm 500 ppm n/a n/a |
đại lý honeywell Minimax XP | nhà phân phối honeywell Minimax XP | thiết bị dò khí honeywell Minimax XP
Construction | |
General | Serviceable, portable single gas monitor for personal protection against Oxygen and toxic gas hazards |
Calibration | Time between calibrations is maximized utilizing cell decay compensation facility. The maximum time between calibrations is 12 months |
Operating Life | Sensor (replaceable) Minimum of 2 years Battery (replaceable) 3 years* |
Operating Temperature | -20°C to +50°C (-4°F to +122°F) (temperature compensated) |
Humidity | 5-95% RH (non-condensing) |
Audible Alarm | 95dB @ 10cm (3.9″) |
Visual Alarm | High intensity Red LEDs |
Vibrating Alarm | Standard |
Display | Ultra clear backlit LCD displays gas levels & instrument status |
Sensor Type | Electrochemical (replaceable) |
Battery Type | Lithium CR2, 3.0v (replaceable) |
Diagnostics | Self-test of circuitry, battery, LCD, and software. Sensor test using patented Reflex † sensor technology |
Environmental | |
IP Rating | IP54 (minimum) |
Intrinsic Safety | North America: Class 1, Div 1, Groups A, B, C, D, T4 (UL/cUL) Europe: II 2G EEx ia IIC T4 (ATEX) |
RFI/EMC | CE EN50270:1999 and EN55011 |
Dimensions | 93mm (H) x 50mm (W) x 27mm(D) (3.6″ x 2″ x 1.1″) excluding clip |
Weight | Toxic 81.5g (2.8oz) Oxygen 93.0g (3.3oz) |